Contact Us

Support EATON UPS System Eaton Make 2 KVA 1:1 Phase On-Line UPS With Internal Batteries - 9E Series

Eaton Make 2 KVA 1:1 Phase On-Line UPS With Internal Batteries - 9E Series

UPS System On Line UPS

33630

Model 9E-IN 2K

Reset default

Specification

Output Specification
Output Capacity (KVA )
2 Kva
Output Capacity (KW )
1.8 Kw
Output Power Factor
0.9 Power Factor
Output Phase
1 Phase
Output Voltage
230 Volt
Other Output Voltage
220 Or 240 Volt
Efficiency at Full Load
> 95 %
Output Voltage Distortion
<3 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Load Crest Factor
3:1
Output Voltage THD
<5 %
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3-wire (1PH+ N + G) & IEC 320 C13
UPS Parallel Upto
Not Available
Input Specification
Input Voltage
230 Volt
Other Input Voltage
220 Or 240 Volt
Input Phase
1 Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
100 - 300 Volt
Input voltage range for main operations
176 - 300 Volt
Input frequency Range
45 - 55 Hz
Input Power Factor
>0.99 None
Input Connections
3-Pin 6A Indian Socket
Batteries & Runtime
Battery DC Bus
48 VDC
Maximum Charger Capacity
Battery Position Option
Internal
Internal Battery Capacity (VAH)
432 VAH
Battery Type Compatibility
SMF Battery
Approved Battery Capacity (AH)
9 - Amp.
Communication & Management
Control panel
LCD Display
SNMP Management
Optional
Power Management Software
In-Built
Audible noise at 1 meter from surface of unit
<40 Decibal
Physical
Maximum Height
327 Mm
Maximum Width
190 Mm
Maximum Depth
399 Mm
Net Weight
17.4 Kg
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Other Specifications
Technology
Double Conversion Online

Features

Eaton 9E-IN - 1-3 KVA Features
General Features
IGBT Based Rectifier True Online Double Conversion Robust design
Wide input voltage range: 160~300VAC @ 100% load(linearly derating to 50% load @ 100VAC input).
Generator Compatible with Wide Input voltage window
Double Conversion Efficiency >91% & ECO mode efficiency up to 98%
100% load @ 0~40C operating temp
Active Input Power Factor Correction 0.99.
O/P power factor 0.9 (O/P power factor 0.8 for long backup model)
Inbuilt OVCD (Over Voltage Cut-off device)
Fully conform coated PCBA adaptable to harsh environment
Offer terminal blocker on 2K/3K rating to connect to big capacity equipment
Digital Charger Technology provide 02-10 A charging current.
Easy understanding LCD for convenient installation setup
WINPOWER software support virtualization transfer application Intelligent Monitoring options.

Documentation

Item Catalogue
9E-IN
pdf

Options

Services