Contact Us

Product UPS System On Line UPS DELTA Make 1 KVA 1:1 Phase Rack Mountable On Line UPS with 50-60 Minutes Back up
DELTA Make 1 KVA 1:1 Phase Rack Mountable On Line UPS with 50-60 Minutes Back up

UPS System On Line UPS

Price: 36740

You save 51904

Output Capacity 1 KVA
Output Phase 1 Phase
Input Phase 1 Phase
Full Load Backup 50-60 Minutes
Back up at 50% Load 100-120 Minutes
Battery DC Bus 24 - VDC
Flexible Battery Option No
Battery Capacity (VAH) 1008 VAH
Maximum Charger Capacity 4 Amp.
Warranty for UPS 24 Month(S)
Warranty for Battery 24 Month(S)
Isolation Transformer Optional
Paralleling Options Not Available
Rack Mountable Yes
Rack Mounting Kit Optional
Battery Rack Yes
Battery Interlink Connectors Yes
Batteries Positioning External
Cabling 5 Meters For Input and Output
Paralleling kit for synchronising Not Available

Reset default

Item Image Item Name Model No. HSN Code Quantity Unit Price Total Price
Delta Make 1 KVA 1:1 Phase Rack Mountable On-Line UPS (R Series)
Delta Make 1 KVA 1:1 Phase Rack Mountable On-Line UPS (R Series)

Amplon New R-1kVA

85049090

1

25960

25960

SMF Batteries 12V-42/45AH
SMF Batteries 12V-42/45AH

SMF12V-42/45 AH

85072000

2

4800

9600

Battery Rack for 02 Nos 12 V-42/45 AH Batteries
Battery Rack for 02 Nos 12 V-42/45 AH Batteries

BR4202

73269099

1

590

590

Interlink Connector for 1 KVA UPS - 24 V DC
Interlink Connector for 1 KVA UPS - 24 V DC

IC-1K-24V

85366990

1

590

590

Grand Total
36740

Options

Item Image Item Name Model No. HSN Code Quantity Unit Price Total Price Add Item
Isolation Transformer for 1 KVA On-Line UPS
Isolation Transformer for 1 KVA On-Line UPS

UNI1KIT

85044090

No.    

6500

6500

Delta Make EBM (Extended Battery Module) with Battery 2x2x9Ah for Amplon New R 1kVA
Delta Make EBM (Extended Battery Module) with Battery 2x2x9Ah for Amplon New R 1kVA

GES022B209035

85072000

No.    

19900

19900

Delta Make MBB (Manual Bypass Box) for Amplon New R 1kVA with (IEC C13x6, C19x1) sockets
Delta Make MBB (Manual Bypass Box) for Amplon New R 1kVA with (IEC C13x6, C19x1) sockets

PDB1211A230035

85049090

No.    

12500

12500

Delta Make Enviro Probe (Use with the SNMP card for temperature sensing with all UPS)
Delta Make Enviro Probe (Use with the SNMP card for temperature sensing with all UPS)

EMS1000000

85049090

No.    

7300

7300

Delta Make New Mini SNMP IPv6 (For INX/N/R/RT/HPH Gen 2.0 use with Mini/Smart Slot in UPS)
Delta Make New Mini SNMP IPv6 (For INX/N/R/RT/HPH Gen 2.0 use with Mini/Smart Slot in UPS)

SCMS100035

85049090

No.    

11000

11000

Delta Make Mini SNMP IPv4 (For INX/N/R/RT/HPH Gen 2.0 use with Mini slot in UPS)
Delta Make Mini SNMP IPv4 (For INX/N/R/RT/HPH Gen 2.0 use with Mini slot in UPS)

3915100473-S

85049090

No.    

7300

7300

Delta Make New Mini Relay I/O card(For INX/N/R/RT/EH/HPH/HPH Gen2.0 use with Mini slot in UPS)
Delta Make New Mini Relay I/O card(For INX/N/R/RT/EH/HPH/HPH Gen2.0 use with Mini slot in UPS)

3915101864-S

85049090

No.    

6500

6500

Delta Make New Mini Modbus I/O Card (For INX/N/R/RT/EH/HPH/HPH Gen 2.0 use with Mini slot in UPS)
Delta Make New Mini Modbus I/O Card (For INX/N/R/RT/EH/HPH/HPH Gen 2.0 use with Mini slot in UPS)

3915101865-S

85049090

No.    

6500

6500

Delta Make Charger Board- 4A/24Vdc for Amplon New R 1kVA for internal extension
Delta Make Charger Board- 4A/24Vdc for Amplon New R 1kVA for internal extension

5505003294-SP

85049090

No.    

8200

8200

Delta Make Charger Box without Charger suitable for Amplon New R 1/2/3kVA
Delta Make Charger Box without Charger suitable for Amplon New R 1/2/3kVA

CHG751C262000-N

85049090

No.    

18200

18200

Delta Make Charger for Amplon New R 1kVA 24V/8A get fitted inside Charger Box CHG751C262000-N
Delta Make Charger for Amplon New R 1kVA 24V/8A get fitted inside Charger Box CHG751C262000-N

5505001897-S-00

85049090

No.    

9700

9700

Documentation

Item Catalogue
Amplon R Series UPS 1-3 KVA Leaflet
pdf