Brand Socomec UPS System Industrial UPS Socomec Make 120 KVA 3:3 Phase Industrial On Line UPS With Built-In Isolation Transformer

Socomec Make 120 KVA 3:3 Phase Industrial On Line UPS With Built-In Isolation Transformer

UPS System Industrial UPS

Price:

You save 0

Resilient transformer-based power protection

The solution for
• Industry
• Processes
• Infrastructure
• Healthcare
• Service sector
• Telecommunications

Advantages
High quality power supply
• Permanent operation in VFI mode (online double conversion).
• Output voltage precision under all load conditions.
• High overload capacity to withstand abnormal load conditions.
• A very high short-circuit current capacity which facilitates the selection of protective devices for selectivity in the downstream distribution.
• An isolation transformer installed on the inverter output to ensure complete galvanic isolation between DC circuit and load output. This insulation also provides a separation between the two inputs when they are supplied by different sources.
• Sinusoidal ThdU output voltage < 2 % with linear loads and < 4 % with non-linear loads.

High availability
• Field-proven technology.
• Fault-tolerant architecture with redundancy of basic functions, such as the ventilation system.
• Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and front access all components.
• Accurate diagnostics guarantee power supply to the load.
• Cascade failure prevention for parallel systems.
• Mechanical & electrical robustness for industrial environments.
• Soft start capability (ramp up) of the IGBT inverter allows a good operation even with a genset.
• Specifically designed to be adapted to different industrial environment: high IP protection options, high peak current capability, long back up time…

Cost-effective equipment
• The "clean" IGBT rectifier allows:
- a high efficiency,
- a high and constant input power factor,
- a low THDi.
These characteristics help to limit the dimensions of upstream network infrastructure.
• Possibility to create new neutral system without additional losses (extra transformer required on by-pass line only).
• High short-circuit capability simplifies downstream protective devices.
• High power density: its small footprint saves space on your premises.
• Mains connection of the rectifier requires only 3 cables (no neutral).
• Battery connection to UPS requires only 2 cables.

User-friendly operation
• A control panel with graphic display for more ergonomic operation.
• An array of "com-slot" plug-in communication interfaces, for upgrading your operating requirements evolution.

Simplified maintenance
• An advanced diagnostic system.
• A remote access device connected to the remote maintenance centre.
• Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).
Model Delphys MP Elite+120K

Reset default

Specification

Output Specification
Output Capacity (KVA )
120 KVA
Output Capacity (KW )
108 KW
Output Power Factor
0.9 Power Factor
Output Phase
3 Phase
Other Output Phase
Or Phase
Output Voltage
400 Volt
Other Output Voltage
380 Or 415 Volt
Efficiency at Full Load
>93.5 %
Output Voltage Distortion
<2 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
Load Crest Factor
3:1
Output Voltage THD
< 3% linear load and <5% non-linear load
Transfer Time
< ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 5-wire (3PH + N + G)
Bypass
Built-in Static Bypass
Overload Capacity
UPS Parallel Upto
Optional
Input Specification
Input Voltage
400 Volt
Other Input Voltage
380 - 415 Volt
Input Phase
3 Phase
Other Input Phase
- Phase
Input frequency
Or Hz
Input frequency Range
45 - 65 Hz
Input Voltage Range (Output Derated)
- Volt
Input voltage range for main operations
340 - 460 Volt
Input Power Factor
>0.99 Power Factor
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input Protection
Input Voltage THD
< %
Input Short Circuit Current (Maximum)
kAmps.
Input Current (Maximum)
Amp.
Batteries & Runtime
Battery Position Option
External
Battery Circuit Breaker
Approved Battery Capacity (AH)
Battery DC Bus
360 - 384 VDC
Battery Type Compatibility
Sealed Maintenance Free (SMF) / Valve Regulated Lead Acid (VRLA) type, Flooded / tubular / vented type
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
Audible Alarm
Audible noise at 1 meter from surface of unit
67 Decibal
Physical
Maximum Height
1930 Mm
Maximum Width
100 Mm
Maximum Depth
800 Mm
Shipping Height
Mm
Shipping Width
Mm
Shipping Depth
Mm
Net Weight
860 Kg
Shipping weight
Kg
Colour
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
- Meters
Storage Temperature
- °C
Storage Relative Humidity
- %
Storage Elevation
- Meters
Online thermal dissipation
Btu/Hr
Protection Class
IP20
Compliances
Compliance
EN/IEC 62040-1, IEC 62040-2, IEC 62040-3, IEC 62040-4
Approvals
Other Environmental Compliance
Other Specifications
Technology
Filtering
Surge Protection

Documentation

Item Catalogue
Socomec Delphys MP Elite Catalogue
pdf