Description

The 9145 double-conversion online UPS from Eaton affordably protects mission-critical applications from downtime, data loss and corruption. Its robust design enables it to operate in harsh physical and electrical environments.

Eaton 9145 UPS - Features

  • Robust design and on-line double conversion topology assures maximum reliability
  • Wide input-voltage range appropriate for the harshest electrical environments
  • Automatic bypass for fault-tolerance
  • Cold start on battery power enables portability
  • Adjustable battery quantity optimises sizing
  • Intuitive front-panel LCD user interface for consistent status indication
  • Inbuilt RS-232, USB & Intelligent Slot communication ports
  • WINPOWER software suite bundled
  • Model 9145 20KXL 31 TX

    Reset default

    Specification

    Output Specification
    Output Capacity (KVA )
    20 KVA
    Output Capacity (KW )
    18 KW
    Output Power Factor
    0.9 Power Factor
    Output Phase
    1 Phase
    Output Voltage
    230 Volt
    Other Output Voltage
    208 Or 240 Volt
    Efficiency at Full Load
    > 92 %
    Output Voltage Distortion
    < 1 %
    Output Frequency (sync to mains)
    50/60Hz +/- 3 Hz
    Load Crest Factor
    3:1
    Output Voltage THD
    < 2 %
    Transfer Time
    < 0 ms
    Output Waveform type
    Sine Wave
    UPS Parallel Upto
    4 Nos.
    Output Connections
    Hard Wire 3 wire (1PH+N+G)
    Input Specification
    Input Voltage
    400 Volt
    Other Input Voltage
    380 Or 415 Volt
    Input Phase
    3 Phase
    Input frequency
    50/60Hz +/- 3 Hz
    Input Voltage Range (Output Derated)
    110 - 276 Volt
    Input voltage range for main operations
    110 - 276 Volt
    Input frequency Range
    45 - 55 Hz
    Input Power Factor
    > 0.99
    Input Connections
    Hard Wire 5-wire (3PH + N + G)
    Batteries & Runtime
    Battery DC Bus
    288 VDC
    Maximum Charger Capacity
    6 Amp.
    Battery Position Option
    External
    Battery Type Compatibility
    SMF / Flooded Batteries
    Batteries Recharge Time upto 90%
    < 5 Hrs.
    Approved Battery Capacity (AH)
    17 - 150 Amp.
    Communication & Management
    SNMP Management
    Optional
    Power Management Software
    In-Built
    Audible noise at 1 meter from surface of unit
    < 55 Decibal
    Control panel
    LCD & LED Display
    Interface Port(s)
    RS-232, USB
    Physical
    Maximum Height
    650 Mm
    Maximum Width
    350 Mm
    Maximum Depth
    890 Mm
    Net Weight
    58.1 Kg
    Environmental
    Operating Temperature
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 % Rh
    Other Specifications
    Technology
    Double Conversion Online