Key Offering Portfolio/Service Portfolio
- Protections IEDs
- Protection relays to fit every application in industrial and distribution utilities: Series 10/20/40/80/380,000+ devices delivered since 2000.
- Protections IEDs
- Proven and recognized MV & HV suite:P*10, P*20, & P*40 Platforms. 600000+ devices delivered since 1997. World leading Arc Protection Specialists
- IEC 61850 Platform: 50 and 200 Series
- Substations Control System
- Pacis 5
Scaleable IEC 61850based Substation Control System 600+ in service since 2002 .
- Pacis 5
- Feeder Automation
- FLITE & FLAIR
Fault detector for overhead and underground networks - SMART RTU
Control units for MV substation and overhead switches with a high level of integrated functions.
- FLITE & FLAIR
- Large RTU/Bay Control
- Modular Substation Computer for flexible operation (RTU, Bay Controller etc.)
BRANDS
MEDIUM VOLTAGE OFFERING
PIX RANGE
- Ratings up to 4,000 A / 40 kA for 12 kV and 17.5 kV range
- Ratings up to 2,500 A and 31.5 kA for 24 kV range
- Single and double busbar, insulated busbar
- Loss of Service Continuity – LSC 2B PM
- Floor, top or rear cable connection
- Back-to-wall or rear access configurations
- Current and voltage transformers on busbar or cable side
- Available with IS current limiter (Fault Current Limiter)
FBX
- SF6-insulated switchgear for secondary distribution network
- SF6 switch-disconnector
- Protection through fuse combination or vacuum circuit-breaker
- Compliant with IEC 62271-200
- Rated Voltage: 12 / 17.5 / 24 kV
- Bus-bar Rated Current: 630 A
- Feeder Rated Current: 630 A
PRIMARY GAS INSULATED SWITCHGEAR
- Modular Design, suitable for Single & Double Bus bar System
- Touch Proof, rapid and safe on site assembly
- User-friendly operator interface with great vareity of cable connection
- GIS (GHA) with no gas handling required at site makes it environment friendly
RINGMASTER
- Touch proof/completely shielded SF6 tank
- Cable testing facility without disconnecting the cables chamber
- Lesser gas leakage points due to moulded construction
- Internal arc AFLR of 21kA 1 sec since the pressure relief device is at the top of the tank
BIOSCO IN 10 & BIOSCO IN 16
- Tested as per IEC 62271-202
- Internal Arc tested solution ensures public and operator safety
- Range IN10-upto 22kV 1000 kVA, IN 16-upto 33 kV 1600 kVA
- HV side with RMU, LV side with ACB & MCCBs
- Oil type and Dry type transformer with optional HT metering & LV APFC panel
E HOUSE
- Fully factory equipped and tested, shipped to site in transportable sections
- Economical & FAST site installation, simplified commissioning
- Increased RELIABILITY, due to assembly/testing/quality control in factory
- Reduce exposure to fatal RISKS in unsafe areas
- Complete switchrooms comprising both MV & LV switchgear plus other equipments like UPS
TRANSFORMERS