Contact Us

Brand Vertiv UPS System Line Interactive UPS Liebert Make 1000 VA Line Interative UPS with 2 X 7 AH Battery

Liebert Make 1000 VA Line Interative UPS with 2 X 7 AH Battery

UPS System Line Interactive UPS

Price: 6714.2

You save 5793.8

Model itON CX 1000 VA

Reset default

Specification

Output Specification
Output Capacity (KVA )
1 Kva
Output Capacity (KW )
0.9 Kw
Output Power Factor
0.99 Power Factor
Output Phase
1 Phase
Output Voltage
220 Volt
Other Output Phase
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Technology
Transfer Time
<0 Ms
Other Output Voltage
Efficiency at Full Load
>90 %
Output Waveform type
Sine Wave
Output Connections
3 Pin Indian Socket (04 Nos.)
Output Voltage Distortion
<2 %
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<3 %
Bypass
Internal Bypass (automatic & manual)
UPS Parallel Upto
Overload Capacity
Optional
Input Specification
Input Voltage
108 Volt
Other Input Voltage
Input Phase
1 Phase
Input frequency Range
40 - 70 Hz
Other Input Phase
Input Connections
3-Pin 6A Indian Socket
Input Protection
Resettable Circuit Breaker
Input frequency
50/60Hz +/- 3 Hz
Input Power Cord Lengh
Input Voltage Range (Output Derated)
Input voltage range for main operations
230 - 240 Volt
Input Power Factor
>0.99
Batteries & Runtime
Battery DC Bus
Maximum Charger Capacity
Battery Position Option
External
Internal Battery Capacity (VAH)
Battery Type Compatibility
SMF Battery
Batteries Recharge Time upto 90%
Approved Battery Capacity (AH)
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
In-Built
Audible Alarm
Audible and visible alarms prioritized by severity
Interface Port(s)
DB-9 RS-232, Smart-Slot
Power Management Software
In-Built
Audible noise at 1 meter from surface of unit
<45 Decibal
Physical
Maximum Height
103 Mm
Maximum Width
405 Mm
Maximum Depth
145 Mm
Net Weight
15 Kg
Shipping weight
Shipping Height
Shipping Width
Shipping Depth
Rack Height(U)
Colour
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
Storage Temperature
-20 - +60 °C
Storage Relative Humidity
Storage Elevation
Audible noise at 1 meter from surface of unit
Compliances
Compliance
IS 16242 (Part1): 2014
Approvals
IS 16242 (Part1): 2014
Other Environmental Compliance
IS 16242 (Part1): 2014
Other Specifications
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Technology
Double Conversion Online
Surge Protection
Yes

Documentation

Item Catalogue
itON CX 1000 VA
pdf

Related Products

No addition BOM required.