Contact Us

Brand Socomec UPS System On Line UPS Socomec Make 20 KVA 3:1 Phase On-Line UPS

Socomec Make 20 KVA 3:1 Phase On-Line UPS

UPS System On Line UPS

Price:

You save 0

Reliable cost-effective power protection

The solution for

Server rooms
Service sector
Infrastructure
Healthcare sector
Light industrial applications

Advantages

Compact, cost-effective protection
Easy to order, install and operate.
State-of-the-art technology providing high levels of performance in a very compact unit.
Online double conversion mode with an output power factor of 0.9 providing 12% more active power compared to UPS with a power factor of 0.8.
Best-in-class online efficiency.
1+1 parallel configuration for 10 kVA and 20 kVA type S models with dual input mains
Innovative battery management extending battery life (virtually ZERO ripple on batteries).
Redundant bypass protection reducing the risk of power cuts.
Integrated LAN network monitoring via web browser. Multilanguage display.
Tailored to your environment
Designed to operate in challenging electrical environments.
Ideal for protecting sensitive IT and non-IT applications.
Flexible battery configurability without changing the footprint.
Up to 3 battery chargers for very long back-up time requirements.
Models with internal isolation transformer and IP31 degree of protection.
IP31 degree of protection available on request for transformerless models.
Low electromagnetic emissions compliant for commercial installations.
Embedded redundancy on the bypass control and power supply to minimise any risk of interrupting the load.
A single 25-block battery string simplifies the connection and reduces both the overall cost and the space required.
Model ITY2-TW210XLB

Reset default

Specification

Output Specification
Output Capacity (KVA )
20 KVA
Output Capacity (KW )
18 KW
Output Power Factor
0.9 Power Factor
Output Phase
1 Phase
Other Output Phase
Or Phase
Output Voltage
220 Volt
Other Output Voltage
230 Or 240 Volt
Efficiency at Full Load
>95 %
Output Voltage Distortion
<1 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<5 %
Transfer Time
<0 ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3 wire (1PH+N+G)
Bypass
Internal Bypass (automatic & manual)
UPS Parallel Upto
Overload Capacity
Optional
Input Specification
Input Voltage
400 Volt
Other Input Voltage
380 Or 415 Volt
Input Phase
3 Phase
Other Input Phase
Or Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
340 - 480 Volt
Input voltage range for main operations
- Volt
Input frequency Range
45 - 55 Hz
Input Power Factor
>0.99 None
Input Connections
Hard Wire 3 wire (1PH+N+G)
Input Protection
Batteries & Runtime
Approved Battery Capacity (AH)
Battery DC Bus
300 - VDC
Maximum Charger Capacity
6 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Batteries Recharge Time upto 90%
<5 Hrs.
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<55 Decibal
Physical
Maximum Height
780 Mm
Maximum Width
370 Mm
Maximum Depth
810 Mm
Shipping Height
Mm
Shipping Width
Mm
Shipping Depth
Mm
Net Weight
58 Kg
Shipping weight
Kg
Rack Height(U)
U
Colour
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
1000 - Meters
Storage Temperature
- °C
Storage Relative Humidity
- % Rh
Storage Elevation
- Meters
Compliances
Compliance
Approvals
Other Environmental Compliance
Other Specifications
Technology
Double Conversion Online
Surge Protection

Documentation

Item Catalogue
Socomac ITYS Pro Catalogue
pdf